Home / Inspection Checklist

HQS Self-Inspection

Pass your Section 8 Housing Quality Standards (HQS) inspection the first time. Walk the unit room by room, mark pass/fail, and print or save a deficiency report.

Critical failure: lead paint

For homes built before 1978 where a child under 6 will live, deteriorated (peeling, chipping, or cracking) paint on interior or exterior surfaces is an inspection failure under HUD's lead-based paint rule (24 CFR 982.401(j)). Even when that rule doesn't apply, defective paint is a common fail item. Fix, scrape, and paint defective surfaces before the inspector arrives.

Health & Safety (Critical)

Most common failure points. Check these first.

  • Working smoke detectors on every level and inside each bedroom — HQS requires smoke detectors on each floor (including basements) and inside every sleeping room. 'Chirping' low-battery alarms are an automatic fail.
  • Carbon monoxide detectors installed (if fuel-burning appliances/garage present) — Required if the unit has gas/oil appliances or an attached garage. Must be operational and usually located within 10ft of bedrooms.
  • No peeling, chipping, or cracking paint (Lead Paint rule - Critical for pre-1978 homes) — For pre-1978 homes: Any deteriorated paint (>2 sq ft interior, >20 sq ft exterior) is a major lead hazard. Must be stabilized (scraped/painted), not just covered.
  • All exterior doors have working locks and no double-keyed deadbolts — Doors must be weather-tight. Double-keyed deadbolts (requiring a key to exit) are a fire entrapment hazard and strictly prohibited.
  • No evidence of roach or rodent infestation — Look for droppings, traps, or holes. Severe infestation is a fail. Minor issues may pass if the landlord has a treatment plan.
  • No trip hazards on floors or stairs (handrails secure) — Carpets must be secured (no fraying/lifting). Stairs with 4+ risers require a secure handrail.

Kitchen

Appliances and plumbing.

  • Stove and oven work properly (all burners ignite without matches) — All burners must light immediately. Oven door must close tightly. Control knobs must be present and legible.
  • Refrigerator cools effectively and door seal is tight — Must maintain safe temps (<40°F). Door gaskets must be intact (no cracks allowing air out).
  • Hot and cold running water with adequate pressure — Check for consistent flow. Low pressure, sputtering, or rust-colored water is a deficiency.
  • No active plumbing leaks under sink — Check under the sink for moisture, rot, or mold. Even a slow drip is a fail.
  • Garbage disposal (if present) is functional — If installed, it must work safely. If broken, it must be repaired or removed/capped. It cannot be left non-functional.
  • Space for food preparation and storage — Adequate cabinetry and counter space required for the family size.

Bathroom

Sanitation and privacy.

  • Toilet flushes and refills properly; acts as a secure base — Must be securely bolted to the floor (no wobble). No running water after flush cycle completes.
  • Fixed washbasin with hot/cold water — Must have a sink with a trap. Leaks, severe rust, or drain clogging are fails.
  • Tub or shower working with hot/cold water — Must have working hot/cold water. Shower walls must be watertight (no missing tiles or rot).
  • Ventilation: Operable window or working exhaust fan — Bathroom must have an openable window OR a working mechanical exhaust fan to prevent mold/mildew.
  • No sewer gas smells or severe mold/mildew — Sewer smell often indicates a dry P-trap or broken wax ring. Severe mold indicates ventilation failure.
  • Bathroom door has a privacy lock — Bathroom must have a door for privacy. A working lock is usually required.

Electrical & Windows

Infrastructure and egress.

  • All light switches and outlets work — Test every switch. Flickering lights, sparking, or warm outlets are major safety fails.
  • Outlet cover plates are intact (no cracks or exposed wiring) — No exposed wires allowed anywhere. Cracked plates must be replaced.
  • GFCI outlets present in wet areas (kitchen/bath) where required — Outlets within 6ft of water source should be GFCI (Ground Fault Circuit Interrupter). Test the reset button.
  • Windows open, stay up without props, and lock properly — Windows must stay up on their own (no prop sticks). Must lock securely. Bedroom windows must be large enough for fire escape.
  • No severe cracks in window glass — Small corner cracks might pass. Large cracks, holes, or missing glass panes are fails (cutting/security hazard).
  • Screens present on windows (if required by local code) — If local code requires screens for ventilation, they must be present and free of large tears.

Heating & Hot Water

Essential systems.

  • Heating system is capable of maintaining 68°F in all rooms — Must provide adequate heat in all habitable rooms directly or indirectly. Portable electric heaters generally don't count as primary heat.
  • Water heater has pressure relief valve and discharge pipe installed correctly — TPR valve must have a discharge pipe extending to within 6-18 inches of the floor. No leaks.
  • Proper ventilation for gas appliances (flues connected) — Gas appliances must be properly vented to exterior. Look for soot marks around vents (backdrafting).
  • 3ft clear space around heating equipment — Combustible materials (boxes, clothes, cleaners) cannot be stored near furnace or water heater.

Frequently Asked Questions

What is a HQS inspection?

Housing Quality Standards (HQS) inspection is required for all Section 8 units. The inspection ensures the property meets minimum health and safety standards set by HUD (24 CFR 982.401). The unit must pass before the Housing Authority will approve the lease and begin payments.

What are the most common HQS inspection failures?

Common failures include: peeling/chipping paint (especially in pre-1978 homes), missing or non-working smoke detectors, double-keyed deadbolts, exposed wiring, missing outlet covers, lack of GFCI outlets in wet areas, water damage or mold, and broken windows or locks. Use our checklist to identify and fix these issues before inspection.

How do I prepare for a Section 8 inspection?

Use our interactive HQS checklist to walk through your property room-by-room. Check all health and safety items first (smoke detectors, egress, electrical), then move through kitchen, bathroom, and other areas. Fix any fail items before scheduling the inspection. Our tool saves your progress and generates a PDF report.

What happens if my property fails the HQS inspection?

If your property fails, the Housing Authority will provide a list of deficiencies. Life-threatening deficiencies generally must be corrected within 24 hours, and other deficiencies within 30 days unless the PHA approves an extension. After repairs, you'll need a re-inspection. For a new tenancy, the PHA won't begin payments until the unit passes.

How long does a HQS inspection take?

A typical HQS inspection takes 30-60 minutes. The inspector will check all rooms, test appliances, verify smoke detectors, check plumbing and electrical systems, and look for health and safety hazards. Having everything prepared beforehand can speed up the process.

Do I need to be present during the inspection?

While not always required, it's highly recommended. Being present allows you to address questions immediately, understand any deficiencies, and potentially fix minor issues on the spot. You can also learn what the inspector is looking for in future inspections.

What is the difference between HQS and NSPIRE?

HQS (Housing Quality Standards) is a room-by-room pass/fail checklist under 24 CFR 982.401. NSPIRE (National Standards for the Physical Inspection of Real Estate) is HUD's newer inspection protocol, scored by severity. Many PHAs still use HQS, but some have switched, so confirm with your PHA which standard applies to your unit. This checklist is a general self-check based on common HQS items and is not a substitute for your PHA's own inspection form.

Can I use photos to prepare for inspection?

Yes. Our AI photo analyzer can help flag potential issues from photos of problem areas. It is a preparation aid only; nothing replaces a thorough in-person walkthrough using the checklist.

Related Tools

Pass Your HQS Inspection
Common failure points and fixes
HAP Contract & Lease
What happens after you pass
Rent Reasonableness
The other check before payments start
Find Your Local PHA
Get your PHA's own inspection form

General guide based on common HUD Housing Quality Standards (24 CFR 982.401). Local PHAs may have additional requirements; always refer to your PHA's landlord packet.